Remedying substandard original work

This Issue This is a part of the Weathertightness feature

By - , Build 119

Undertaking weathertightness surveys may also identify other building work that needs to be done – some problems may only become evident after remedial work has begun.

Figure 1: Undersized lintels that have sagged will need to be assessed by a structural engineer to determine the options available – whether they can be left or need to be replaced.

Retaining a weather tightness specialist through the construction phase of a remediation project is recommended, particularly for designers new to these projects. When problems other than weathertightness are identified, there is a duty of care to advise the owner of the extent of the problems.

Problems can be widespread

Examples of problems that may be identified during a project remediation include:

  • inadequate structural performance in terms of bracing provided, spans of rafters, beams and lintels, undersized framing members
  • lack of fire performance of inter-tenancy walls and floors or boundary walls
  • lack of acoustic performance of inter-tenancy walls and floors
  • incorrect location of the building on the site – this is a difficult problem to address, legal input to adjust boundaries or create easements will be required
  • flashing details not following good practice, for example, a lack of cover or contacting surfaces
  • missing damp-proof membrane
  • load-bearing walls that are not effectively supported by joists or bearers
  • unconsented (or illegal) work that has been carried out on the property.

Moisture problems may include:

  • high levels of subfloor moisture and a lack of subfloor ventilation
  • high levels of internal moisture – often due to a lack of ventilation and/or heating
  • leaking bathrooms or plumbing
  • failure of wet area waterproofing, particularly in tiled showers
  • evidence of plumbing leaks
  • basement waterproofing failure.

Safety issues identified may include:

  • no handrails to stairs
  • inadequate barrier heights and construction within and around the building
  • unsafe barriers, for example, safety glass has not been used where it should be
  • unsafe structures, for example, a block wall that has not had all cells filled with grout as specified
  • hazardous materials.
Figure 1: Undersized lintels that have sagged will need to be assessed by a structural engineer to determine the options available – whether they can be left or need to be replaced.

A general lack of maintenance or repair can be an issue including:

  • blocked downpipes
  • paintwork in poor condition
  • stormwater or sewer drainage that is blocked, lacks fall or is missing completely
  • a material that has reached the end of its serviceable life
  • corrosion of steel framing, fixings/flashings.

The ability or need to undertake this work will be influenced by:

  • whether the work is legally required to be done – where a building is deemed to be structurally unsafe or unsanitary, there is a statutory obligation to remedy the situation (see Figure 1)
  • the owner’s circumstances – do they have the resources (and the will) to do work that is discretionary?
  • whether the work is considered essential or desirable – a leaking bathroom or shower would fall into the essential category
  • a positive assessment of the costs of doing the work versus the benefits gained – it can be difficult to assign a dollar value to benefits such as a warmer house
  • the age of the building – for example, a building that is more than 5 years old is likely to be insulated to older lower standards and therefore the benefit of doing the upgrade is greater
  • the additional risks associated with the work
  • the condition of the building – has maintenance been deferred for some time?
  • the current (realistic) selling price of the building and the estimated selling price once repaired, estimated for each repair option.