Page 42 - Build 161
P. 42

Figure 2
Aluminium window installation – head detail.
Figure 3
Timber window installation – head detail.
steel angle lintel sized to suit opening
100 mm seating for spans up to 2.0 m wide opening
200 mm seating for spans over 2.0 m long
sealant required between underside of head  ashing and top edge of window head  ange for VH and EH wind zones
aluminium window frame
timber reveal
 exible  ashing over opening, bedded in mortar joint and carried 200 mm beyond jamb line
50 mm minimum upstand
head  ashing with 15° slope and stop-ended to edge of bricks
steel angle lintel sized to suit opening
continuous air seal over backing rod
timber head
40 — August/September 2017 — Build 161
wall underlay or  exible  ashing tape lapped over  exible  ashing
 exible  ashing over opening, bedded in mortar joint and carried 200 mm beyond jamb line (weepholes to be provided in course above the  ashing)
insulation
 exible  ashing tape to  ashing upstand
50 mm minimum upstand
head  ashing with 15° slope and stop-ended to edge of bricks
continuous air seal over backing rod
wall underlay turned into window opening with  exible  ashing tape to corners
wall underlay or  exible  ashing tape lapped over  exible  ashing (weepholes to be provided in course above  ashing)
 exible  ashing tape to  ashing upstand
100 mm seating for spans up to 2.0 m wide opening
200 mm seating for spans over 2.0 m wide
5 mm gap between steel lintel and  ashing
masonry veneer
5 mm gap
timber window


































































































   40   41   42   43   44